Outlets for Washer/Dryer Combo | Information by Electrical ...
2017年9月11日 · Hello, If there is a stacked Washer/Dryer combo in a dedicated closet do i need to have one receptacle for washer and one for the dryer or one 30A-2P will take care of both the washer and the dryer? 210.11C(2) says that i need to have at least one additional 20 amp branch circuit to supply the...
30A/2P stacked washer/dryer...is 20A laundry circuit still required?
2010年3月11日 · I have been double dipping in my calcs, counting the 1500W laundry circuit plus the full 30A/2P washer/dryer load. I think going forward I should continue showing the laundry circuit with the "eliminate it if you can" note, but should stop calculating the laundry circuit twice - just go with the 30A/2P load only.
Stacked Washer/Dryer | Information by Electrical Professionals for ...
2011年6月29日 · I have also seen them require just a DP 30 amp circuit. I have also seen washer that require 240V. There are a lot of different units out there. I would calculate using 1500 watts for the washer and 5000 for the dryer since I believe the code requires the 1500 watts for the washer anyway.
location for stack dryer outlet | Information by Electrical ...
2017年4月11日 · Hi , Ive never ran the circuit for one of the stack type washer dryer combinations . I am told they use the same 230 v 30 amp plug and cord as a regular dryer and the washer is on the same circuit . My question is what is the best location as far a height and centering on the closet back wall for the dryer outlet .
Whirlpool WET4124HW 120 volts | Information by Electrical …
2018年8月10日 · I had a job today installing a new 120 volt circuit for a 24" stacked washer/dryer. The owner swapped out their old machine (240 volt) for a new machine. The new machine looks identical but is designed to run on 120 volts. I have been involved with lots of …
30A/2P stacked washer/dryer...is 20A laundry circuit still required?
2010年3月11日 · 4000W - nameplate of electric dryer-----5500W total With a stacked single-point installation your calcs look like this: 1500W - laundry circuit 5500W - nameplate of washer/dryer-----7000W total I made up the nameplates out of thin air, but you get the idea. The same thing is essentially being installed: a washer and a dryer.
Stack unit washer and dryer | Information by Electrical …
2015年4月22日 · IMO, there is a required 120V receptacle needed for the washer and since it is closer than 6' to a sink it would require gfci. The 240V 30 amp receptacle does not require one. rcarroll
Laundry Dryer requires AFCI GFCI protection? | Information by ...
2023年8月13日 · Looked for an answer online and found that topic, so the correct answer seems to be: in dwelling units dryer receptacle should be GFCI protected NEC 2020 210.8(A) Dwelling Units.
Laundry Dedicated circuit | Information by Electrical Professionals …
2021年3月15日 · I have a project where the architects have located (1) stacked washer/dryers (in each multifamily unit) in a closet. This space is enclosed, and identified as laundry space. There is no accessible space within the closet for the code required dedicated laundry receptacle. Is it …
Commercial Laundromat | Information by Electrical Professionals …
2022年9月1日 · Combined washer name plates is 225 amps, 120 volt gas dryers combined name plate is 466 amps. Total in just washer and dryer power is 691 amps. I would think that would fall in the continuous load category. 691a x 1.25 which would be 863 amps in just washer and dryers. Then have to factor in lighting, hvac, water heater, receptacles.